T型固定式定值分流器
发布日期:2025-06-17 浏览量:331
主要技术参数MAIN TECHNICAL DATA
◆参数范围 Parameter range: 150A~2.5KA /10mV~300mV;
2.51KA~10KA /10mV~150mV
◆准确度等级 Accuracy class: ±0.25,±0.3,±0.5,±1.0
◆电阻温度系数 Temperature coefficient: ≤40ppm
◆环境条件Ambient condition: -40~ +70℃
◆相对湿度Relative humidity: ≤95%
◆耐机械力性能:能承受加速度为70米/秒2及冲击频率每分钟80~120次6小时的运输颠震。
Capacity to wishstad mechanical force: It is capable of withstanding the transport bumping at acceleration of 70m/s2 and shock frequency of 80-120 times/mi for 6hr.
◆温升:额定电流下持续2小时温升变化趋于稳定后,额定电流100A以下不超过80℃;额定电流100A以上温升不超过120℃。
Temperature rise:Put in rated current for 2hr, after the temperature rising steady test it: When the rated current less than 100A,the temperature rise should be no more than 80℃;When the rated current more than 100A, the temperature rise should be no more than 120℃.
◆过负载性能:120%额定电流值,2小时。
Over load performance: 120% of rated current for 2hours.
◆热电势影响:不超过等级指数的50%。
Thermoelectric potential influence: no more than 50% of the index level.
用途USE
该款固定式定值分流器广泛用于扩大仪表测量电流范围。
The interchangeable shunts are used to multiply the measuring range of current of measuring instruments.
应用领域APPLICATION
◆电信通信设备 Telecommunications equipment
◆电动汽车 Electric cars
◆航空航天 Aerospace
◆新能源设备及储能系统 New Energy Equipment and Energy Storage Systems
◆电镀电源 Electroplating Power Equipment
◆仪器仪表 Instrument and meter,
◆直流输变电系统 Dc power system
适用标准 APPLICABLE STANDARDS
◆GB/T7676-2017《直接作用模拟指示电测量仪表及其附件》
GB/T7676-2017《Direct acting indicating analogue electrcai measuring instruments and their accessories》
◆IEC 61010-1:2001《测量、控制和实验室用的电气设备的安全要求 第一部份: 通用要求》
IEC 61010-1:2001《Safety requirements for electrical equipment for measurement,control,and laboratory use part 1: General Requirements》
◆SJ/T 11363-2006《电子信息产品中有毒有害物质的限量要求》 欧盟:ROHS 2.0 2011/65/EU
SJ/T 11363-2006《Requirements for concentration limits for certain hazardous substances in electronic information products》 European Union ROHS 2.0 《2011/65/EU》